Square millimetres, B&S and AWG: cable size units explained

Up to date as of 29 November 2026

Cable is sold in three common labels. Square millimetres (mm²) measure the area of the copper. AWG and B&S use gauge numbers. They describe the same thing, but they don't match one for one.

Matching one size label to anotherRead the label on the cableFind its area in square millimetresCompare with the chart's sizePick the next size up if between
Convert to cross-section area so you compare like with like.

What each label means

Square millimetres. This is the metric way. It's based directly on the cross-section area of the wire, in mm². Wikipedia notes that this is the metric standard used in most parts of the world, and that it differs from AWG1. A bigger number means a thicker cable.

AWG. American Wire Gauge. Here the numbers run backward. Wikipedia says increasing gauge numbers mean decreasing wire diameters1. So 4 AWG is thicker than 12 AWG. Very thick sizes use number-and-zero labels such as 1/0 and 2/0.

B&S. Brown & Sharpe. Wikipedia describes AWG as essentially identical to the Brown & Sharpe sheet metal gauge, though using B&S for wire is technically improper1. If a label says B&S, treat it as the same gauge numbers and check the maker's own table if you can.

How they line up

Why bother converting? Because charts use one label and shops sell another. One maker's table pairs the two for each size. Here are a few rows from it.

AWG Area
12 AWG 3.31 mm²2
8 AWG 8.37 mm²2
4 AWG 21.20 mm²2

Area is the part that counts. Wikipedia says the cross-section area of each gauge is an important factor for working out its current-carrying capacity1.

Metric and AWG sizes don't match exactly

Metric cable comes in its own standard steps. AWG comes in its own. They land close but not on the same figure. One maker's solar cable table says common panel cable is typically 12 AWG (4 mm²) or 10 AWG (6 mm²)3. Its other guide lists 12 AWG as 3.31 mm²2. Two guides, two roundings.

So what if a chart wants a size the shop doesn't stock? Don't go smaller. A thicker cable loses less voltage, and a thinner one can overheat. Check the chart's own notes, or ask the equipment maker.

Side by side: working in metric or in AWG

Working in mm² Working in AWG
Number meaning Bigger is thicker Smaller is thicker
Suits Buyers in Australia, New Zealand, the UK and most of Europe Charts and parts from North America
Watch for Odd steps between standard sizes Charts that print a mm² figure that's slightly rounded

The first row follows from the sources above. The second row is a general guide to who tends to see which label.

Stranded cable counts too

Wikipedia says a stranded wire will always be slightly larger overall than a solid wire of the same AWG1. So don't judge a cable by its outside width, because the insulation adds to it as well. Read the printed size.

Isolate the battery first on any cable job in a vehicle, boat or off-grid system, and follow the equipment maker's manual. Fixed mains wiring is licensed electrical work in Australia. Book a licensed electrician for it.

To put these sizes to use, the chart-reading page is next.

Sources used

  1. American wire gauge, Wikipedia
  2. Cable Wire Gauge Selection Guide for DC Systems, Renogy
  3. Renogy Wire and Fuse Sizing Guide, Renogy